Strany 1 - XT300C, XT302C Deluxe

1Pub. No. 22-5127-0469-1214OWNER’S GUIDE(XT300C shown)XT300C, XT302C DeluxeProgrammable Heat-Cool Thermostats69-1214Pub. No. 22-5127-04

Strany 2 - TABLE OF CONTENTS

10Pub. No. 22-5127-0469-1214FEATURES YOU’LL WANT TOKNOW MORE ABOUTComfort-R Comfort Enhancement SystemComfort can best be described as the proper bala

Strany 3

11Pub. No. 22-5127-0469-1214Adaptive Intelligent Recovery ControlYour Thermostat Senses TemperatureMore Like You DoYour new thermostat is so smart, it

Strany 4

12Pub. No. 22-5127-0469-1214After installation or new schedule programming, yourthermostat learns from experience. How? Each day itchecks how closely

Strany 5 - CUSTOMIZING YOUR THERMOSTAT

13Pub. No. 22-5127-0469-1214AMPMSUN MON TUE WED THU FRI SAT COOL ON HEAT ONWAKE LEAVE RETURN NIGHT TEMPORARY UNOCCUI

Strany 6

14Pub. No. 22-5127-0469-1214NEAT STUFF YOU’LL BE USING OFTENSetting Temporary TemperaturesIf your thermostat is set for 7-Day or 24-Hour Operation, yo

Strany 7 - GETTING AROUND THE KEYBOARD

15Pub. No. 22-5127-0469-1214The temporary temperature setting you select displays for approximately 3 seconds. The display readsTemporary until the ne

Strany 8

16Pub. No. 22-5127-0469-1214Changing Temperature Setting IndefinitelyNOTE: This feature does not apply to Constant Temperature Setpoint Programming.NO

Strany 9 - FEATURES

17Pub. No. 22-5127-0469-12142. Press Increase ▲ or Decrease ▼ tochange the temperature setpoint, if desired.M17041AutoFanHeatSettingSystemHeatBy pres

Strany 10 - KNOW MORE ABOUT

18Pub. No. 22-5127-0469-12144. Press Increase ▲ or Decrease ▼ to adjusttemperature settings.M17043AutoFanCoolSettingSystemHeatPressing the Temperatur

Strany 11 - Pub. No. 22-5127-04

19Pub. No. 22-5127-0469-1214Vacation ModeNOTE: This feature does not apply to Constant Temperature Setpoint Programming.1. Press Hold Temp twice.Press

Strany 12 - Energy Savings Solution

2Pub. No. 22-5127-0469-1214TABLE OF CONTENTSCUSTOMIZING YOUR THERMOSTAT ...

Strany 13

20Pub. No. 22-5127-0469-1214TimeM17037AutoFanHeatFri DaysWakeHold forSettingSystemHeatLeaveWake Return Sleep2. Press Time ▲ or Time ▼ until the desir

Strany 14 - Temporary Setting

21Pub. No. 22-5127-0469-12144. Press Increase ▲ or Decrease ▼ to adjustthe temperature setting, if desired.M17039AutoFanHeatDaysFriHold forSettingSys

Strany 15

22Pub. No. 22-5127-0469-1214IMPORTANTTo cancel the Hold before the designated time, press Run Program.RunProgramPressed the wrong key?Want to start ov

Strany 16

23Pub. No. 22-5127-0469-1214Information KeyThe Information key provides information at yourfingertips. The sequence of key presses is as follows:• Out

Strany 17

24Pub. No. 22-5127-0469-1214Displaying Current SettingsPress twice to check the currenttemperature setpoint. Press three timesto check the temperatur

Strany 18

25Pub. No. 22-5127-0469-1214M17047FILTER EXPIRATION INDICATORFilter IndicationYour thermostat monitors the time the fan is runningand lets you know wh

Strany 19 - Hold Temp

26Pub. No. 22-5127-0469-1214Setting or Resetting Filter Indication TimerYour thermostat comes preset to the 30-day setting. To change this setting, or

Strany 20

27Pub. No. 22-5127-0469-12143. Press Time ▲ or Time ▼ until the desired number of days displays (0, 7, 14, 21, 30, 45, 60, 90,120, 180, 270, or 360).

Strany 21

28Pub. No. 22-5127-0469-1214PROGRAMMING YOUR THERMOSTATClockSetting Current Day and TimeIMPORTANTAlways press the keys with your fingertip or similar

Strany 22 - Want to start over?

29Pub. No. 22-5127-0469-12141. Press Set Current Day/Time.M17050PMMonSet Day/TimeSet CurrentDay/TimePressing Set Current Day/Time displays the informa

Strany 23 - Information Key

3Pub. No. 22-5127-0469-1214Filter Indication ...

Strany 24 - Displaying Current Settings

30Pub. No. 22-5127-0469-12143. Press Time ▲ or Time ▼ until thecurrent time displays.NOTE: Tapping Set Current Day/Time advances the time inone-hour

Strany 25 - Filter Indication

31Pub. No. 22-5127-0469-1214Setting System and FanThe system default setting is Heat and the fan default setting is Auto. Use the System and Fan keys

Strany 26

32Pub. No. 22-5127-0469-12147-Day Program and OperationYour thermostat comes preset for 7-Day Operation unless otherwise noted on page 6. After review

Strany 27

33Pub. No. 22-5127-0469-1214Table 1. 7-Day Preprogrammed Schedule.WAKE LEAVE RETURN SLEEPSUNDAY TIME 6:00 AMFAN AUTOH 70 C 78TIME 8:00 AMFAN AUTO H

Strany 28 - PROGRAMMING YOUR THERMOSTAT

34Pub. No. 22-5127-0469-1214Customizing Your Own 7-Day ScheduleBefore starting the programming procedure, use Tables 2 and 3 to organize your schedule

Strany 29

35Pub. No. 22-5127-0469-1214Instructions1. Write in the time you want each schedule period to begin.2. Write in the heating temperature (H) and coolin

Strany 30

36Pub. No. 22-5127-0469-1214Table 2. Your 7-Day Schedule.WAKE LEAVE RETURN SLEEPSUNDAY TIMEFAN AUTO ONH CTIMEFAN AUTO ONH CTIMEFAN AUTO ONH CTIM

Strany 31 - Setting System and Fan

37Pub. No. 22-5127-0469-1214Table 3. An Extra 7-Day Schedule.WAKE LEAVE RETURN SLEEPSUNDAY TIMEFAN AUTO ONH CTIMEFAN AUTO ONH CTIMEFAN AUTO ONH

Strany 32 - 7-Day Program and Operation

38Pub. No. 22-5127-0469-1214Programming the First DayTo modify the preprogrammed schedule, start by programming the Wake time and temperature and fan

Strany 33

39Pub. No. 22-5127-0469-12142. Press Day until the desired daydisplays.DayM17057HeatAutoFanWakeAMMonSet ProgramSettingBy pressing Day, you select the

Strany 34 - A Word About Power Outages

4Pub. No. 22-5127-0469-1214TROUBLESHOOTING...

Strany 35

40Pub. No. 22-5127-0469-12144. Press Increase ▲ or Decrease ▼ untilthe desired Wake temperature displays.NOTE: The setpoint temperature rangeis 55 to

Strany 36 - Table 2. Your 7-Day Schedule

41Pub. No. 22-5127-0469-12145. Press Heat/Cool Settings to make selec-tions for the opposite system setting (eitherHeat or Cool).NOTE: If your system

Strany 37

42Pub. No. 22-5127-0469-1214Leave Return SleepRunProgram7. Press Leave, Return or Sleep and repeat steps 3, 4, 5 and 6 for programming the rest of the

Strany 38 - 1. Press Wake

43Pub. No. 22-5127-0469-1214Copying a DayNOTE: The copy feature applies only to 7-Day Operation. The thermostat must be in the program mode to usethe

Strany 39

44Pub. No. 22-5127-0469-12143. Press Copy.CopyM17063MonBy pressing Copy, you copy a day’s schedule into memory.Example display shows Monday’s schedule

Strany 40

45Pub. No. 22-5127-0469-12145. Press Copy.NOTE: donE displays for two secondsbefore the normal displayreturns.RunProgramCopyM17065By pressing Copy aga

Strany 41

46Pub. No. 22-5127-0469-1214Clearing Schedule PeriodSuppose you want to skip a schedule period or periods for a particular day because you don’t need

Strany 42

47Pub. No. 22-5127-0469-12142. For 7-Day Operation, press Day until thedesired day displays. For 24-HourOperation, skip to step 3.DayM17067HeatAutoFan

Strany 43

48Pub. No. 22-5127-0469-1214You do not have to program a replacement time for the remaining periods, for example Wake and Sleep. If youcleared only th

Strany 44

49Pub. No. 22-5127-0469-121424-Hour Program and Operation24-Hour Operation is the same as 7-Day Operation exceptthe same program repeats itself each d

Strany 45

5Pub. No. 22-5127-0469-1214CUSTOMIZING YOUR THERMOSTATProgram Options Set-Up by Your Trane DealerYour Trane dealer has programmed your thermostat usin

Strany 46 - Leave Return Sleep

50Pub. No. 22-5127-0469-1214The preprogrammed schedule is as follows (same schedule for all days of the week): You may keep thisschedule or organize y

Strany 47

51Pub. No. 22-5127-0469-1214Instructions1. Write in the time you want each schedule period to begin.2. Write in the heating temperature (H) and coolin

Strany 48

52Pub. No. 22-5127-0469-12141. Press Wake.TimeWakeM17069HeatAutoFanWakeAMMonTueWedThuFriSat SunSet ProgramSettingBy pressing Wake, you enter the progr

Strany 49 - 24-Hour Program and Operation

53Pub. No. 22-5127-0469-12143. Press Increase ▲ or Decrease ▼ untilthe desired Wake temperature displays.NOTE: The setpoint temperature rangeis 55 to

Strany 50

54Pub. No. 22-5127-0469-1214Heat/CoolSettings4. Press Heat/Cool Settings to makeselections for the opposite systemsetting (either Heat or Cool).NOTE:

Strany 51

55Pub. No. 22-5127-0469-12145. Press Increase ▲or Decrease ▼until the desired temperature setpointdisplays.By pressing Increase ▲ or Decrease ▼, you s

Strany 52

56Pub. No. 22-5127-0469-1214Constant TemperatureSetpoint ProgrammingUnlike the first two options, Constant TemperatureSetpoint Programming does not ha

Strany 53

57Pub. No. 22-5127-0469-12141. Press Increase ▲ or Decrease ▼ untilthe desired temperature displays.NOTE: The setpoint temperature rangeis 55 to 85°F

Strany 54

58Pub. No. 22-5127-0469-12143. Press Increase ▲ or Decrease ▼until the desired temperature setpointdisplays.By pressing Increase ▲ or Decrease ▼ after

Strany 55

59Pub. No. 22-5127-0469-1214TROUBLESHOOTING GUIDE(continued)Symptom Possible Cause ActionDisplay does not comeon.Thermostat is not beingpowered.Check

Strany 56 - Setpoint Programming

6Pub. No. 22-5127-0469-1214NOTE: The XT300C, XT302C thermostats are manufactured for the Trane Company by Honeywell Inc. Specificfeatures are unique t

Strany 57

60Pub. No. 22-5127-0469-1214Troubleshooting Guide (continued)(continued)Symptom Possible Cause ActionHeating does not comeon.No power to the thermosta

Strany 58

61Pub. No. 22-5127-0469-1214Troubleshooting Guide (continued)Symptom Possible Cause ActionSystem on indicator(flame=heat,snowflake=cool) is lit, butno

Strany 59 - TROUBLESHOOTING GUIDE

62Pub. No. 22-5127-0469-1214DEFINITIONSAdaptive Intelligent Recovery™ ControlAdaptive Intelligent Recovery™ Control is the factory default setting tha

Strany 60 - (continued)

63Pub. No. 22-5127-0469-1214If your thermostat is set to conventional recovery, a ❑ indica-tion displays continuously, as shown on the example display

Strany 61

64Pub. No. 22-5127-0469-1214Preprogrammed ScheduleThe preprogrammed schedule consists of the four periods (Wake, Leave, Return and Sleep) and accompan

Strany 62 - DEFINITIONS

65Pub. No. 22-5127-0469-1214INDEX24-Hour Operation, 4924-Hour Preprogrammed Schedule, 507-Day Operation, 327-Day Preprogrammed Schedule, 33Adaptive In

Strany 63

66Pub. No. 22-5127-0469-1214LIMITED WARRANTYLow Voltage Room ThermostatsThis warranty is extended by American Standard Inc., to the original purchaser

Strany 64

67Pub. No. 22-5127-0469-1214CUSTOMER ASSISTANCEIf, after reading this guide, you have any questions concerning the operation of your thermostat, pleas

Strany 65

68Pub. No. 22-5127-0469-1214Pub. No. 22-5127-04T8600, T862469-1214 1-99 T.C.American Standard Inc.Troup HighwayTyler, TX 75711-9010Printed in Tai

Strany 66 - LIMITED WARRANTY

7Pub. No. 22-5127-0469-1214GETTING AROUND THE KEYBOARDThe keyboard is located behind the thermostat cover. Three frequently used keys are located next

Strany 67 - CUSTOMER ASSISTANCE

8Pub. No. 22-5127-0469-1214M17031ATimeSet ProgramSystemFilter FanRunProgramHold TempSet CurrentDay/TimeWakeLeaveReturn SleepDayHeat/CoolSettingsDaylig

Strany 68

9Pub. No. 22-5127-0469-1214FEATURES• Worry-free programming.• Comfort-R Comfort Enhancement Process—aunique Trane feature.• Adaptive Intelligent Recov