Strany 1 - Force–Flo™ Cabinet Heater

Air Terminal DevicesHorizontal and VerticalSizes 02-12Force–Flo™ Cabinet Heater CAB-PRC001-ENDecember 2000

Strany 2

General DataCAB-PRC001-EN10Model EHorizontal RecessedInletBottom StampedLouverFresh AirTop or BackOutletFront Duct CollarUnitConfigurationsModel FVert

Strany 3 - Contents

General DataCAB-PRC001-EN 11Model J Vertical Cabinet Slope TopInletFront Toe Space,Front Bar GrilleFresh AirBottom or BackOutletTop Quad Grille, Top B

Strany 4 - Benefits

General DataCAB-PRC001-EN12OutletFront StampedLouverModel MInverted Vertical CabinetInletFront StampedLouverOutletFront StampedLouverModel NInverted V

Strany 5 - Description

General DataCAB-PRC001-EN 13Table GD-1. Force–Flo Cabinet Heater General DataUnit Size 0 2 0 3 0 4 0 6 0 8 1 0 1 2Coil DataFace Area — Ft2 (cm2) 0.8 (

Strany 6

General DataCAB-PRC001-EN14Electric HeatAll Force-Flo™ cabinet heaters, exceptinverted models M and N, are availablewith electric heating coils as a s

Strany 7

General DataCAB-PRC001-EN 15Factory-Installed PipingPackagesForce–Flo cabinet heaters have standardpiping packages available as a factorybuilt and ins

Strany 8

General DataCAB-PRC001-EN16Piping PackagesPiping Package OptionsAutomatic Circuit Setter (C)Manual

Strany 9

General DataCAB-PRC001-EN 17Selecting the CorrectModulating Valve SizeModulating valves are available in any offour port sizes. These four port sizesr

Strany 10 - Configurations

PerformanceDataCAB-PRC001-EN18Hot WaterCoilsForce–Flo cabinet heater performance data is grouped based on performance. Unitperformance is impacted by

Strany 11

PerformanceDataCAB-PRC001-EN 19Hot WaterCoilsHeating performance is based on 70 F (21 C) entering air temperature, 180 F (82 C) entering hot water tem

Strany 12

©American Standard Inc. 2000 CAB-PRC001-ENIt isn’t just a fan and a coil…The Trane Company has redesigned the traditional cabinet heater to lead the i

Strany 13

PerformanceDataCAB-PRC001-EN20Hot WaterCoilsHeating performance is based on 70 F (21 C) entering air temperature, 180 F (82 C) entering hot water temp

Strany 14 - Electric Heat

PerformanceDataCAB-PRC001-EN 21Hot WaterCoilsHeating performance is based on 70 F (21 C) entering air temperature, 180 F (82 C) entering hot water tem

Strany 15 - Piping Packages

PerformanceDataCAB-PRC001-EN22SteamCoilsHeating performance is based on 70 F (21 C) entering air temperature, 2 psig (14 kPa) and 5 psig (103 kPa) ent

Strany 16

PerformanceDataCAB-PRC001-EN 23SteamCoilsHeating performance is based on 70 F (21 C) entering air temperature, 2 psig (14 kPa) and 5 psig (103 kPa) en

Strany 17

ControlsCAB-PRC001-EN24ZN.010 Control BoardZN.510 Control BoardControl OptionsForce–Flo cabinet heaters are available with four different control opti

Strany 18 - Hot Water

ControlsCAB-PRC001-EN 25Sequence ofOperationSequence of OperationFan Speed SwitchOff: Fan is turned off, two-positiondamper option spring-returns clos

Strany 19

ControlsCAB-PRC001-EN26GeneralInformationTable C-1. Controller Input/Output Summary ZN.010 ZN.510 ZN.520Binary Outputs3-Speed Fan ===2-P

Strany 20

ControlsCAB-PRC001-EN 27Zone Sensor OptionsZone sensors are available as either unit,wall, or split-mounted options for designflexibility. Cabinet hea

Strany 21

ControlsCAB-PRC001-EN28Control FeaturesThe following control functions arestandard features on units with TracerZN.010, ZN.510, or ZN.520.Occupied/Uno

Strany 22

ControlsCAB-PRC001-EN 29End DeviceOptionsEnd Device OptionsAll end device options are factory-installed and tested.Two-Position Control ValvesModel Nu

Strany 23

CAB-PRC001-EN 3ContentsIntroduction 2Features and Benefits 4Selection Procedure 5Model Number Description 5General Data 7Performance Data 18Hot Water

Strany 24 - Controls

Electrical Data30CAB-PRC001-ENMinimum Circuit Ampacity(MCA) and Maximum FuseSize (MFS) CalculationsUnits with Electric HeatHACR (heating, air conditio

Strany 25 - Sequence of

Electrical DataCAB-PRC001-EN 31Table ED-2. Free Discharge Motors on Units with Two-Row, Electric, or Steam Coils115 Volt 208-230 Volt 277-480 Volt RPM

Strany 26 - Information

Electrical Data32CAB-PRC001-ENTable ED-6. Two-Stage Electric Heat (Digit 18 = U)Unit 1st Stage Total TotalSize Volts Hz Ph Wires kW kW Amps/ph208 1 2

Strany 27 - Zone Sensor

Electrical DataCAB-PRC001-EN 33Table ED-8. Single Stage, Low kW Electric Heat (Digit 18 = V)Unit Size Voltage # Wires kW Amps/ph kW Amps/ph kW Amps/ph

Strany 28 - Features

Dimensionsand WeightsCAB-PRC001-EN34Table DW-1. Operating Weights — lbs. (kg)Unit Cabinet Concealed RecessedSize Models Models Models0 2 97 (44) 81 (3

Strany 29

Dimensionsand WeightsCAB-PRC001-EN 35VerticalConcealedVertical Concealed, Model AVertical Concealed Unit DimensionsUnitSize 02-03 04 06 08 10-12

Strany 30 - Electrical Data

Dimensionsand WeightsCAB-PRC001-EN36Vertical CabinetVertical Cabinet, Model BVertical Cabinet Unit DimensionsUnitSize 02-03 04 06 08 10-12A2’-9

Strany 31

Dimensionsand WeightsCAB-PRC001-EN 37HorizontalConcealedHorizontal Concealed, Model CHorizontal Concealed Unit DimensionsUnitSize 02-03 04 06 08

Strany 32

Dimensionsand WeightsCAB-PRC001-EN38HorizontalCabinetHorizontal Cabinet, Model DHorizontal Cabinet Unit DimensionsUnitSize 02-03 04 06 08 10-12A

Strany 33

Dimensionsand WeightsCAB-PRC001-EN 39HorizontalRecessedHorizontal Recessed, Model EHorizontal Recessed Unit DimensionsUnitSize 02-03 04 06 08 10

Strany 34 - Dimensions

Features andBenefitsCAB-PRC001-EN4The Force–Flo™ cabinet heater meets thestandards of today’s market, as well asthe anticipated needs of tomorrow’smar

Strany 35 - Concealed

Dimensionsand WeightsCAB-PRC001-EN40VerticalWall HungVertical Wall Hung Cabinet, Model FVertical Wall Hung Cabinet Unit DimensionsUnitSize 02-03 04

Strany 36 - Vertical Cabinet

Dimensionsand WeightsCAB-PRC001-EN 41VerticalRecessedVertical Recessed, Model HVertical Recessed Unit DimensionsUnitSize 02-03 04 06 08 10-12A2’

Strany 37 - Horizontal

Dimensionsand WeightsCAB-PRC001-EN42VerticalSlope TopVertical Slope Top, Model JVertical Slope Top Unit DimensionsUnitSize 02-03 04 06 08 10-12A

Strany 38

Dimensionsand WeightsCAB-PRC001-EN 43Inverted Vertical Cabinet, Model MInverted VerticalCabinet Inverted

Strany 39 - Recessed

Dimensionsand WeightsCAB-PRC001-EN44Inverted VerticalRecessedInverted Vertical Recessed, Model NInverted Vertical Recessed Unit DimensionsUnitSize 02

Strany 40 - Wall Hung

Dimensionsand WeightsCAB-PRC001-EN 45CoilConnectionsCoil Connections,Vertical UnitsCoil Connections,Horizontal UnitsHR - Hot Water ReturnHS - Hot Wate

Strany 41

Dimensionsand WeightsCAB-PRC001-EN46Fresh AirOpeningFresh Air Opening LocationsHorizontal Units Models C, D, and EFresh Air Opening Dimensions, Horizo

Strany 42 - Slope Top

Dimensionsand WeightsCAB-PRC001-EN 47Fresh Air Opening LocationsVertical Units Models A, B, F, and JFresh Air Opening Dimensions, Vertical UnitsUnitSi

Strany 43 -

Dimensionsand WeightsCAB-PRC001-EN48Wall Box DimensionsUnit Size Dimensions InternalRef. Only A x B Supports02 - 03 24 3/8 x 4 3/410 4 24 3/8 x 7 1

Strany 44 - Inverted Vertical

Dimensionsand WeightsCAB-PRC001-EN 49Projection PanelProjection Panel, All Unit SizesC2” 2 1/2” 3” 3 1/2” 4” 4 1/2” 5” 5 1/2” 6”D1 1/8“ 1 5/8“ 2 1/8“

Strany 45 - HS - Hot Water Supply

SelectionProcedureCAB-PRC001-EN 5Digit 20 — Coil Air VentA = Automatic Air VentM= Manual Air VentDigits 21, 22, 23 — Electric Heat kW(208V Derate)000

Strany 46 - Fresh Air

MechanicalSpecificationsCAB-PRC001-EN50Force–Flo™ Cabinet HeaterMechanical SpecificationsPerformance DataCapacity: Unit capacities are in accor-dance

Strany 47 - WALL HUNG

MechanicalSpecificationsCAB-PRC001-EN 51Three-Way, Two-Position Control ValvesNormally open three-way, two-positionvalves are rated for a maximum 25 p

Strany 48 - Wall Box

MechanicalSpecificationsCAB-PRC001-EN52Disconnect SwitchA unit mounted disconnect switch isavailable as a standard option on all units.ColorsSix decor

Strany 49 - Projection Panel

MechanicalSpecificationsCAB-PRC001-EN 53False BacksFalse backs increase the depth of avertical cabinet unit and provide a cavitythrough which to run p

Strany 50 - Specifications

MechanicalSpecificationsCAB-PRC001-EN54Piping ComponentsBall ValvePart Material Spec ASTMLever Steel, zinc platedSeat Teflon VTFEPacking Teflon RTFESt

Strany 51

MechanicalSpecificationsCAB-PRC001-EN 55Control ValveMaterialBody — Forged BrassStem — Chrome-Plated Brass (Modulating) Nickel Plated (2-Position)Seat

Strany 52

The Trane CompanyA Division of American StandardInc.www.trane.comFor more information contactyour local Trane office ore-mail us at [email protected]

Strany 53

SelectionProcedureCAB-PRC001-EN6Note: Please contact your local Trane sales representative for buildable digit combinations.Model NumberDescriptionDig

Strany 54

General DataCAB-PRC001-EN 7Model AVertical ConcealedModel BVertical CabinetInletFront Toe SpaceFresh AirBottom or BackOutletTop Duct CollarInletFront

Strany 55

General DataCAB-PRC001-EN8Model CHorizontal ConcealedUnitConfigurationsInletBack Duct CollarOutletFront Duct CollarFresh AirN/AFresh AirN/AOutletFron

Strany 56

General DataCAB-PRC001-EN 9Model DHorizontal CabinetUnitConfigurationsInletBottom StampedLouverOutletFront QuadGrille, Front Bar GrilleFresh AirTop o

Komentáře k této Příručce