12 GTND-SVX01B-EN
Unit Dimensions and Weights
Ta b l e 1. Unit sizes 30–120: Performance and specification data
Unit Size 30 45 60 75 90 105 120
PERFORMANCE DATA
(a)
Input Btu/h 30,000 45,000 60,000 75,000 90,000 105,000 120,000
(kW) (8.8) (13.2) (17.6) (22.0) (26.4) (30.8) (35.2)
Output Btu/h 24,900 37,350 49,800 61,500 73,800 86,100 98,400
(kW) (7.2) (10.9) (14.5) (18.0) (21.6) (25.2) (28.8)
Thermal Efficiency %83838382828282
Free Air Delivery CFM cfm 370 550 740 920 1,100 1,300 1,475
(m
3
/s) (0.175) (0.260) (0.349) (0.434) (0.519) (0.614) (0.696)
Air Temperature Rise °F 60 60 60 60 60 60 60
(°C) (15) (15) (15) (15) (15) (15) (15)
Full Load Amps at 115V 3.0 3.0 4.1 4.1 6.4 6.4 6.4
Maximum Circuit Ampacity 3.5 3.5 4.8 4.8 7.5 7.5 7.5
MOTOR DATA:
Motor hp 1/20 1/20 1/12 1/12 1/10 1/10 1/10
(kW) (0.04) (0.04) (0.06) (0.06) (0.075) (0.075) (0.075)
Type SP SP SP SP SP SP SP
RPM 1650165010501050105010501050
Amps @ 115V 1.9 1.9 2.6 2.6 4.2 4.2 4.2
DIMENSIONAL DATA
A” Jacket Height in. 12-3/8 12-3/815-7/815-7/822-5/822-5/822-5/8
(mm) (314) (314) (403) (403) (574) (574) (574)
“B” Overall Height in. 13-1/4 13-1/4 16-13/16 16-13/16 23-9/16 23-9/16 23-9/16
(mm) (337) (337) (427) (427) (598) (598) (598)
“C” Overall Depth in. 25-7/8 25-7/8 26-3/16 26-3/16 26-3/8 26-3/8 26-3/8
(mm) (632) (632) (665) (665) (670) (670) (670)
“D1” Center Line Height of Flue
(b)
in. 8-1/2 8-1/2 10-3/8 10-3/8 13-5/8 13-5/8 13-5/8
(mm) (216) (216) (263) (263) (346) (346) (346)
“D2” Center Line Height of Air Intake in. 8-1/2 8-1/2 8 8 8-5/8 8-5/8 8-5/8
(mm) (216) (216) (203) (203) (219) (219) (219)
E Fan Diameter in.10101414161616
(mm) (254) (254) (356) (356) (406) (406) (406)
“F” Discharge Opening Height in. 10-13/16 10-13/16 14-7/16 14-7/16 21-3/16 21-3/16 21-3/16
(mm) (275) (275) (367) (367) (538) (538) (538)
“G” Vent Connection Diameter in. 4 4 4 4 4 4 4
(mm) (102) (102) (102) (102) (102) (102) (102)
“H1” Center Line of Flue Connection From Side in. 7-1/4 7-1/4 7-1/4 7-1/4 7-3/4 7-3/4 7-3/4
(mm) (184) (184) (184) (184) (197) (197) (197)
“H2” Center Line of Air Intake From Side in. 2-3/4 2-3/4 2-3/4 2-3/4 3-1/2 3-1/2 3-1/2
(mm) (70) (70) (70) (70) (89) (89) (89)
Vent Size Requirements - Standard Combustion
Category I Horizontal
(c)
in.4445555
(mm) (102) (102) (102) (127) (127) (127) (127)
Category III Horizontal in.4444444
(mm) (102) (102) (102) (102) (102) (102) (102)
Category I & III Vertical in.4444444
(mm) (102) (102) (102) (102) (102) (102) (102)
Vent Size Requirements - Separated Combustion
Exhaust Diameter** in.4444555
(mm) (102) (102) (102) (102) (127) (127) (127)
Intake Air Diameter in.4444555
(mm) (102) (102) (102) (102) (127) (127) (127)
Unit Weight lb 60 65 80 85 95 105 110
(kg) (27) (29) (36) (39) (43) (48) (50)
Shipping Weight lb 70 75 90 95 110 115 120
(kg) (32) (34) (41) (43) (50) (52) (54)
(a) Ratings shown are for unit installations at elevations between 0 and 2000 ft. (610 m). For unit installations in USA above 2000 ft. (610 m), the unit
input must be derated 4% for each 1000 ft. (305 m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the
National Gas Code, ANSI Standard Z223.1 (N.F.P.A. No. 54). Also refer to Table 10, p. 42.
For installations in Canada, any reference to deration at altitudes in excess of 2000 ft. (610 m) are to be ignored. At altitudes of 2000 to 4500 ft. (610
to 1372 m), the unit must be derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification.
(b)For all installations, the flue collar is included with the unit and should be field-installed per the instructions included with the unit.
(c) 4”–5” reducer supplied where required.